ZHOU Xue-feng. Design of a new type of protection circuit of mine-used intrinsic safety power supply[J]. Journal of Mine Automation, 2013, 39(7): 101-103.
Citation: ZHOU Xue-feng. Design of a new type of protection circuit of mine-used intrinsic safety power supply[J]. Journal of Mine Automation, 2013, 39(7): 101-103.

Design of a new type of protection circuit of mine-used intrinsic safety power supply

More Information
  • The paper put forward a design scheme of a new type of protection circuit of mine-used intrinsic safety power supply with LM339 comparator and MAX4080SASA current detection chip based on the analysis of advantages and disadvantages of traditional protection circuit of mine-used intrinsic safety power supply, and analyzed principle and characteristics of the design scheme, which provided a high-quality solution for design of mine-used intrinsic safety power supply.
  • Related Articles

    [1]BAO Changjun, LI Jiping, GENG Wenjing, YU Zhixue, CUI Shijie. Sequences selection research on over-voltage and over-current protection for intrinsic safety power supply[J]. Journal of Mine Automation, 2019, 45(1): 57-64.. DOI: 10.13272/j.issn.1671-251x.2018050095
    [2]REN Gaojian, LU Yuanxiang, YOU Qingshan, FU Shaohua. A testing device for intrinsically safe multi-circuit protection power supply[J]. Journal of Mine Automation, 2018, 44(1): 44-49. DOI: 10.13272/j.issn.1671-251x.2018.01.002
    [3]JIAO Xiaofeng. Application of symmetrical component method in protection system of bolter-miner[J]. Journal of Mine Automation, 2017, 43(10): 14-17. DOI: 10.13272/j.issn.1671-251x.2017.10.003
    [4]FANG Xupeng, YU Zhixue, QIN Ming, YAN Peng, ZHAO Ke. A novel chopping current protection circuit for intrinsically safe power supply[J]. Journal of Mine Automation, 2016, 42(12): 56-58. DOI: 10.13272/j.issn.1671-251x.2016.12.012
    [5]XIE Guojun, WANG Tongsheng, WANG Shufeng, ZHU Chengjia. Design of protection module of intrinsic safety power supply based on LT4356[J]. Journal of Mine Automation, 2014, 40(12): 80-83. DOI: 10.13272/j.issn.1671-251x.2014.12.021
    [6]LIU Qi. Design analysis of mine-used intrinsic safety power supply[J]. Journal of Mine Automation, 2014, 40(4): 84-86. DOI: 10.13272/j.issn.1671-251x.2014.04.020
    [7]YANG Sheng-yua. Design of new time-delay protection circuit for voltage-loss of high-voltage flameproof switch[J]. Journal of Mine Automation, 2013, 39(11): 110-112. DOI: 10.7526/j.issn.1671-251X.2013.11.029
    [8]ZHANG Cun-zhu, WANG De-guang. Implementation of Asymmetric Over-current Protection of Low-voltage Power Network of Mine[J]. Journal of Mine Automation, 2009, 35(12): 98-100.
    [9]ZHOU You-li. Development of Intelligent Type Electronic Over-load Protection Relay of Motor Based on LPC2292[J]. Journal of Mine Automation, 2009, 35(6): 107-111.

Catalog

    Article Metrics

    Article views (72) PDF downloads (18) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return