LIU Zhong-fu~, LIU Zhong-qiang~, YANG Ya-ning~. Research of Integrated Protection System of High-voltage Flameproof Switch Based on Multi-CPU Control[J]. Journal of Mine Automation, 2008, 34(6): 1-5.
Citation: LIU Zhong-fu~, LIU Zhong-qiang~, YANG Ya-ning~. Research of Integrated Protection System of High-voltage Flameproof Switch Based on Multi-CPU Control[J]. Journal of Mine Automation, 2008, 34(6): 1-5.

Research of Integrated Protection System of High-voltage Flameproof Switch Based on Multi-CPU Control

More Information
  • Aiming at the problems of little ability of current carrying,simple protection, high fault rate of flameproof switch for underground 6 kV power grid,the paper proposed a design scheme of integrated protection system of high-voltage flameproof switch based on multi-CPU control,analyzed working(principle) of fault protection of 6 kV high-voltage power grid of coal mine underground,and introduced(design) of hardware and software of the system in details.The integrated protection system of high-voltage flameproof switch based on multi-CPU control used(single-chip) microcomputer MSP430F149 and DSP TMS320VC5402 as main controllers,and the main(controllers) synthetically analyzed all kinds of signals of power grid in order to realize function of general monitoring for high-voltage power grid.The experiment(result) showed that the system is stable in running,reliable in action and accurate in display.
  • Related Articles

    [1]LI Wenfeng, CAI Pengbo. Design of intrinsically safe laser auxiliary light source for low-illumination video acquisitio[J]. Journal of Mine Automation, 2019, 45(1): 13-17. DOI: 10.13272/j.issn.1671-251x.2018090058
    [2]YU Zhixue, FANG Xupeng, ZHAO Yang. Design of novel intrinsically safe power supply with "ia" grade[J]. Journal of Mine Automation, 2017, 43(8): 83-86. DOI: 10.13272/j.issn.1671-251x.2017.08.016
    [3]LIU Ya-hui, GUO Jiang-tao, LIN Yin. Design of mine-used adaptive wide-voltage power supply with explosion-proof and intrinsic safety[J]. Journal of Mine Automation, 2013, 39(4): 36-39.
    [4]ZHAO Guang-xu. Design of Intrinsic Safety Current-frequency Conversion Circuit Based on PIC Single-chip Microcomputer[J]. Journal of Mine Automation, 2012, 38(10): 70-72.
    [5]LI Xiao-jun, LONG Xian-jiang, ZHANG Qing-a. DTHZ-20 Intrinsically Safe Type Electromagnet for Unloading Valve Used in Mine[J]. Journal of Mine Automation, 2010, 36(9): 15-18.
    [6]LI Xiao-ju. DXH-13.2/5 Intrinsically Safe Type Portable Power Supply[J]. Journal of Mine Automation, 2010, 36(3): 19-21.
    [7]ZHANG Xing-hua, LIU Yu-ying, FENG Xiao-long, WANG Hong-jian, JIANG Hai-ming. Design of Intrinsically Safe and Digitized UPS[J]. Journal of Mine Automation, 2008, 34(5): 72-74.
    [8]WANG Lei, LI Zhen-bi. A New Type of Power Supply of Intrinsic Safety[J]. Journal of Mine Automation, 2008, 34(2): 82-84.
    [9]CHEN Zi-chun, LIU Xiang-qi. Model BQZ1-400/4.5.6 Combined Vacuum Magnetic Starter of Flameproof and Intrinsic Safety Used in Mine[J]. Journal of Mine Automation, 2005, 31(2): 66-67.

Catalog

    Article Metrics

    Article views (33) PDF downloads (0) Cited by()