KANG Qian, XU Chunyu, TIAN Muqin, SONG Jiancheng. Design of high-power intrinsically safe power supply based on fault current change rate[J]. Journal of Mine Automation, 2021, 47(2): 6-12. DOI: 10.13272/j.issn.1671-251x.2020110035
Citation: KANG Qian, XU Chunyu, TIAN Muqin, SONG Jiancheng. Design of high-power intrinsically safe power supply based on fault current change rate[J]. Journal of Mine Automation, 2021, 47(2): 6-12. DOI: 10.13272/j.issn.1671-251x.2020110035

Design of high-power intrinsically safe power supply based on fault current change rate

More Information
  • Published Date: February 19, 2021
  • In order to solve the problems of low output power, poor protection effect, and slow dynamic response speed of existing intrinsically safe power supply, a high-power intrinsically safe power supply based on fault current change rate is designed. The intrinsically safe power supply is equivalent to an EC circuit, and the short-circuit fault characteristics of the EC circuit are analyzed as follows: the spark discharge current rises rapidly at the initial stage of the short-circuit, and the current change rate changes suddenly. By detecting the value of change rate of the fault current in the circuit after a short-circuit fault, it is able to predict the fault state in advance, trigger the protection function before the fault current reaching the protection threshold set by the conventional current protection method, and cut off the output circuit at the initial stage of the short-circuit fault so as to increase the output power of the intrinsically safe power supply. The high power intrinsically safe power supply includes 2 parts: the switching power supply and the intrinsically safe protection circuit. The switching power supply adopts flyback converter structure. The core of the control circuit is UC3842, and the core of the feedback circuit is optocoupler and three-terminal regulator TL431. The intrinsically safe protection circuit limits the energy of spark discharge according to the change rate of the fault current, and mainly includes a fault detection circuit, a comparison circuit, a self-recovery circuit, a soft start circuit and a drive circuit. The performance test results of the intrinsically safe power supply prototype show that the power factor of the intrinsically safe power supply is not less than 0.96 when the AC input voltage fluctuating in the range of 90 to 265 V, the output DC voltage ripple is within 20 mV, and the efficiency of the power supply is above 85%. The short-circuit test results show that the transient output energy of the intrinsically safe power supply after a short-circuit fault is 65 μJ, which meets the design requirements.
  • Related Articles

    [1]ZHANG Min, WU Xinghua, GENG Pulong, SONG Jiancheng, NIU Honghui, TIAN Dexiang. Influence of insulation resistance asymmetry of mine power cable on AC stray current distributio[J]. Journal of Mine Automation, 2019, 45(2): 65-69. DOI: 10.13272/j.issn.1671-251x.2018080001
    [2]LI Ke, SUI Xiaona, ZHANG Jun, ZHANG Feifei, LI He, ZOU Wei. Research on fault line selection method of mine power network[J]. Journal of Mine Automation, 2018, 44(5): 70-75. DOI: 10.13272/j.issn.1671-251x.2018010024
    [3]ZHANG Yun-xing. Analysis of Measuring Methods of Grounding Insulation Resistance and Distributed Capacitance of Underground Low-voltage Power Grid[J]. Journal of Mine Automation, 2011, 37(6): 93-97.
    [4]QI Yan, HE Ren-wang, WU Xu. A Protection Algorithm of Filtering Decaying DC Component[J]. Journal of Mine Automation, 2011, 37(3): 36-39.
    [5]GAO Yu. Development of a Leakage Protector with Additional DC Source[J]. Journal of Mine Automation, 2010, 36(4): 22-24.
    [6]WANG De-sheng. Application of Additional DC Power SUpply Detection Method in Leakage Protectio[J]. Journal of Mine Automation, 2010, 36(2): 62-64.
    [7]LI Bin, YUAN Zhen-hai. Study of Principle of Selective Leakage Protection of Zero Sequence DC of Low-voltage Power Network Underground and Its Implementatio[J]. Journal of Mine Automation, 2007, 33(1): 57-59.
    [8]SHEN Xiang-yun, YUAN Zhen-hai. Study on Selective Leakage Protection System Based on Natural DC[J]. Journal of Mine Automation, 2004, 30(2): 10-13.
    [9]ZHANG Jin-bo, LI Zhi-jin, KE Xiao-gan, CHEN Xiao-gang. Circuit Design of a High-voltage Generator of Digital Measuring Instrument for Insulation Resistance[J]. Journal of Mine Automation, 2002, 28(5): 27-28.
    [10]LI Gang , CAI Xu . A New Type Integrated Device of DC Insulation Monitoring and Earth Point Locating[J]. Journal of Mine Automation, 2001, 27(5): 22-24.

Catalog

    Article Metrics

    Article views (128) PDF downloads (28) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return