用相位递推法确定三相变压器的联接组

林春英

林春英. 用相位递推法确定三相变压器的联接组[J]. 工矿自动化, 2005, 31(6): 28-29.
引用本文: 林春英. 用相位递推法确定三相变压器的联接组[J]. 工矿自动化, 2005, 31(6): 28-29.
LIN Chun-ying. Applying the Phase Recurrence Algorithm to Decide Connection Group of Three-phase Transformer[J]. Journal of Mine Automation, 2005, 31(6): 28-29.
Citation: LIN Chun-ying. Applying the Phase Recurrence Algorithm to Decide Connection Group of Three-phase Transformer[J]. Journal of Mine Automation, 2005, 31(6): 28-29.

用相位递推法确定三相变压器的联接组

Applying the Phase Recurrence Algorithm to Decide Connection Group of Three-phase Transformer

  • 摘要: 文章给出了一种快速判断三相变压器联接组的方法———相位递推法,这种方法和相量图法比较具有简单、快速、准确的特点。
    Abstract: The phase recurrence algorithm that estimates connection group of three-phase transformer fleetly was given in this article.Compared with the phasor graph method,the phase recurrence algorithm has the advantages of simpleness,speediness and accuracy.