Abstract:
In order to meet the different requirements of coal mine monitoring, positioning, video, audio, remote control, 5G and other services for latency, reliability, bandwidth and other indicators, the coal mine information comprehensive bearer network should have the following functions. ① The network slicing function supports FlexE interface technology or channelized sub interface technology, and divides port bandwidth resources into different network slices. The services between different network slices are isolated and carried by each other without affecting each other. ② The online bandwidth expansion function of network slicing ensures that there is no packet loss during the bandwidth adjustment process. ③ Network slices set the power-off protection function. ④ The network complies with IEEE 802.3 and TCP/IP protocols, supports IPv6 protocol and IPv6 service bearer, and supports both IPv4 and IPv6 services simultaneously. ⑤ The network supports 10GE optical interface, 1GE optical interface, 10/100/1000 Mbit/s adaptive interface. The core and aggregation nodes should support optical interfaces of 50GE or above. ⑥ It is advisable to use a circular or double ring structure. ⑦ The real time monitoring function for business quality, monitors the delay, jitter, and packet loss rate of specified services in real time. ⑧ 1588v2 clock synchronization function supports 5G base station service access. The main technical indicators of the coal mine information comprehensive bearer network should meet the following requirements. ① The optical port transmission distance should be ≥ 20 km. The transmission distance of the electrical port should be ≥ 100 meters. ② The transmission rate of the backbone network should be ≥ 10 Gbit/s. The transmission rate of the access network should be ≥ 1 Gbit/s. ③ The packet loss rate for different frame lengths is ≤ 0.01% (under 70% network traffic load conditions). ④ The single node transmission delay should be ≤ 1 ms (when the Ethernet frame length is 1518 bytes). ⑤ Node forwarding jitter should be ≤100 μs. ⑥ The number of slices supported by a single interface should be ≥ 5. ⑦ The minimum bandwidth of FlexE interface technology should be ≤1 Gbit/s. The minimum bandwidth of channelized sub interface technology should be ≤ 2 Mbit/s. ⑧ The self-healing time of network reconstruction should be ≤ 50 ms. ⑨ After a power outage in the power grid, the continuous working time of the bearer network equipment under standby power supply should be ≥ 4 hours.