Exterior ventilation leakage test and reform of Fengchishan Coal Mine
-
摘要: 针对凤翅山煤矿兼做行人和运料通道的回风副斜井外部漏风现象严重的现状,采用风表直接测定法对选取的测点进行了矿井外部漏风测试,根据外部漏风率的变化确定了防爆风门绞车绳通行窗口为矿井主要漏风源;针对原有绞车绳通行窗口采用橡胶皮垫固定在防爆风门上进行封闭的方法容易导致漏风的问题,提出了采用移动挡板封闭窗口的改造方案。测定结果表明,改造后的矿井外部漏风率由原来的15.5%降至6.5%,通风机负压减小了318 Pa。Abstract: In view of status of serious exterior ventilation leakage of auxiliary inclined air returning shaft used for staff and material transportation in Fengchishan Coal Mine, wind meter direct measuring method was used to test mine exterior ventilation leakage of selected test points, winch rope access window of explosion-proof ventilation door was determined as main ventilation leakage source according to change of exterior ventilation leakage rate. In view of problem that original closed method of winch rope access window easily led to ventilation leakage by use of rubber pad to fix on explosion-proof ventilation door, a reform scheme by use of movable baffle to close the window was proposed. The test results show that exterior ventilation leakage rate is reduced from 15.5% to 6.5% and negative pressure of ventilator is reduced by 318 Pa after reform.