  • 摘要: 针对现有二极管钳位式(NPC)三电平逆变器开路故障诊断方法存在计算量大、准确率受噪声和负载等影响的问题,提出了一种基于Park变换的三电平逆变器开路故障诊断方法。对三电平逆变器三相输出电流进行Park变换,计算平均电流Park矢量;利用滑动窗口取得单周期电流信号,根据逆变器电路结构分析IGBT故障时输出电流变化;采用迭代法确定平均电流Park矢量模值的阈值,结合相角和模值进行三电平逆变器功率管13种开路故障的识别和定位。仿真结果表明,该方法故障诊断准确率达到了98.31%。与传统的开路故障诊断方法相比,该方法不需要对13种开路故障数据进行学习和训练,大大减少了计算量,提高了故障诊断效率和准确率。

     