Volume 36 Issue 4
Apr.  2010
Turn off MathJax
Article Contents
ZHANG Fei, FAN Wen-sheng, SUN Jian-ling, et al. Determination of Reasonable Size of Protection Pillars for Crossheading on Super Long Working Face[J]. Industry and Mine Automation, 2010, 36(4): 36-40.
Citation: ZHANG Fei, FAN Wen-sheng, SUN Jian-ling, et al. Determination of Reasonable Size of Protection Pillars for Crossheading on Super Long Working Face[J]. Industry and Mine Automation, 2010, 36(4): 36-40.

Determination of Reasonable Size of Protection Pillars for Crossheading on Super Long Working Face

  • For production test of 300 m fully mechanized working face of caving coal in Lutian coal mine of Haibowan mining Co., Ltd. of Shenhua group, FLAC3D was used to determinate reasonable size of crossheading pillars affected by mining. Through establishing model and simulation, conclusions are as following: along with lengthening of working face,periodic weighting eases,so as to reduce impact to crossheading pillars to some extent; coal pillars which are influenced with the maximum range are 100~110 m away from the rear area of working face, laterally significant affect range is about 10 m, and depth of plastic damage is 7 m; because protection pillar will be influenced by next working, the size of the protection pillar of super long working face with shallow depth under the same geological conditions is 15 m.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (34) PDF downloads(3) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return