The paper put forward requirements of installation, use, maintenance and management of coal mine safety monitoring and control system. It proposed flameproof and intrinsically safe power supply is prohibited where power could be out off, adjustment which would cause power of local ventilators off should be done once every 6 months, and monitoring data must be uploaded to dispatching command center of mining bureau (company) or country (city). It put forward requirements of installation, use and management of underground personnel position monitoring system. It proposed devices should be equipped at each well head for personnel in or out to detect whether identification cards are normal as well as uniqueness detection based on face recognition or iris recognition, and personnel position monitoring substation should be installed at each well head for personnel in or out, exit and entrance in important area, restricted area, tunnel branch and other places.