Research of Underground Electromagnetic Interference Sources and Anti-interference Technology
-
摘要: 针对煤矿井下电磁环境恶劣而导致安全监控系统经常出现误报警、误断电现象的问题,分析了煤矿井下电磁干扰源种类,并对某矿安全监控系统发生误报警的区域进行了电磁干扰测试。测试结果表明,该矿3213工作面腰巷、风巷动力电缆和测试电线并行长度约为150 m时,沿线水泵、钻机启动时产生的对外线路感应浪涌信号的干扰强度峰峰值达190 V,干扰强度较大,说明变频器和钻机同时启动时产生了强烈的信号干扰源,导致瓦斯传感器出现误报警现象。根据测试结果提出了相应的抗干扰措施,解决了瓦斯传感器的误报警问题。Abstract: In view of problem that bad electromagnetic environment of coal mine underground causes phenomenon of false alarm and false power off of safety monitoring and control system, the paper analyzed kinds of underground electromagnetic interference sources and made electromagnetic interference test in areas of false alarm of safety monitoring and control system of a coal mine. The test result showed that on No.3213 working face of the mine, when parallel length of power cable and test cable in waist roadway and airway is about 150 m, interference peak-peak value of induced surge generated by starting pumps and drills is as high as 190 V, and the interference intensity is strong, which explained that strong signal interference sources produced by simultaneous starting of frequency converter and drill caused phenomenon of false alarm of gas sensor. According to the test result, it proposed corresponding anti-interference measures which solved problem of false alarm of gas sensor
点击查看大图
计量
- 文章访问数: 58
- HTML全文浏览量: 12
- PDF下载量: 11
- 被引次数: 0