摘要: 分析了煤矿井下中性点不接地供电系统对地绝缘电阻的基本要求,给出了附加直流电源检测对地绝缘电阻的原理与保护方法;在此基础上介绍了一种附加直流电源漏电保护器的软、硬件设计方案。实验和实际运行结果表明,该附加直流电源漏电保护器误差较小,能够满足煤矿井下电网的漏电保护要求。Abstract: Basic requirements of insulation resistance between isolated neutral power supply system of coal mine underground and ground were analyzed and principle and protection method of detecting insulation resistance by additional DC source were given. On the basis, a design scheme of software and hardware of leakage protector with additional DC source was introduced. The results of experiment and actual running showed that the leakage protector has small error and can meet requirement of leakage protection of underground power network.