2001 Vol. 27, No. 1

Display Method:
Analog Outstation for Testing Performances of Mine Monitoring and Control System and Its Linking Methods
SUN Ji-ping
2001, 27(1): 1-3.
Abstract:
The paper studies the analog outstation for testing performarces of mine monitoring and control system and its linking methods used in model checking, flameproof checking, ex factory checking, installation and maintenance. These methods have been adopted by “General Specification of Information Transmission Device Used in Coal Mine” and “Main Performance Testing Methods of Coal Monitoring and Control System” which are coal industry standards.
The Integration of Server Fault-tolerant and Disk Array Technique
SHI Chun-he , ZHOU Xin-lian
2001, 27(1): 3-5.
Abstract:
The paper introduced 2 of server fault tolerant techniques in common use. And it expounds in details the basic principle of RAID technique. At last it gives a integrated example of engineering.
Research on Expert System for Predicting Floor Water-irruptio
CHEN Xue-xing, LIU Wei-tao, ZHANG Wen-qua
2001, 27(1): 5-8.
Abstract:
Study on Improving Steady-state Accuracy of Fuzzy Controller with Mathematical Method
WANG Yan, ZHANG Fu-en
2001, 27(1): 9-10.
Abstract:
The paper analyzes the cause of bad steady state accuracy existed in common fuzzy controller, and puts forward a scheme with mathematical method to improve steady state accuracy of fuzzy controller. At last it gives the artificial testing results of the improved fuzzy controller.
Design of Serial Communication of Computer Monitoring System with Infrared Transmissio
QIU Jian-cai
2001, 27(1): 11-13.
Abstract:
The Principle and Method of Measurement of Telemetering Module of the Remote Terminal Unit
SHANG Li-qun
2001, 27(1): 13-15.
Abstract:
In this paper the principle and method of measurement of telemetering module of the remote terminal unit is introduced. The error of AC sampling method is analyzed and a method of reducing error is given.
Selection of Voltmeter and Current Meter for SCR Phase-controlled Equipment
LIU Xiao-li, CHENG Ji-xu
2001, 27(1): 16-17.
Abstract:
Application of Circuit Transformer Bank in Small-scale Heat Power Plant in Coal Mine and Its Protection Distributio
ZOU Yi-wen, LI Jin-he
2001, 27(1): 18-20.
Abstract:
Transformer bank has some advantages, such as simple in wiring and distribution, economic in investment, little in occupy floor. The paper discusses the feasibility of transformer bank used in small scale heat power plant in coal mine and its relaying protection distribution.
The Terminal Device of Production Dispatching System for Truck Based on Single-chip Microcomputer
LI Kai-sheng, ZHANG Hui-hui, ZHAN Ya
2001, 27(1): 21-22.
Abstract:
The Safety Monitoring and Control System Used in Coal Mine
CHEN Yong-li , CHEN Li-jun , CHEN Peng , ZHAO Xia , LIU Ming , WANG Xiao-ming
2001, 27(1): 23-25.
Abstract:
The paper introduces a monitoring and control system for coal mine safety realized by serial communication between the 8031 single chip microcomputer and PC computer, and the design of its hardware and software.
The Vacuum Reform of the QC83-80N Flameproof Magnetic Force Starter with Reversible Air Contactors Used in Mine
ZHANG Xing-rong, YANG Yi, CUI Wen-qiang, LI An-ping, SONG Jian-cheng
2001, 27(1): 25-27.
Abstract:
This paper presents the characteristics of the vaccum reform of the QC83-80N flameproof magnetic force starter with reversible air contactors used in mine. The reformed switch has adopted JDB-80N electronic complex protector to protect control motor from short circuit, overload, openphase and lock for leakage, etc. The combination of new mechanical interlocking mechanism and control circuit can lock reversible vaccum contactors not only in electricity but also in mechanism, which improves the interlocking reliability of two contactors.
The Upgrading of Model KJ95 Comprehensive Monitoring and Control System
WANG Xiao-yang
2001, 27(1): 28-29.
Abstract:
Fault Analysis and Phase Debugging Method of the Thyristor Charger
YANG Wei-zhen
2001, 27(1): 29-31.
Abstract:
It is analyzed that voltage phase characteristics when the thyristor charger is wried in different ways and the phase shift characteristic of the thyristor rectification circuit. The voltage phasor diagram is drawed. The phase debugging method of the thyristor rectification circuit is introduced.
A Solution to Bus Trouble of CA
HAN Ju
2001, 27(1): 32-33.
Abstract:
Design and Realization of Object-oriented Monitoring Configuration Software of Coal Mine Safety and Productio
MENG Qian, ZHOU Yan, YU Hong-zhe
2001, 27(1): 34-35.
Abstract:
Analysis of Existing Problems of Incoming and Outgoing Line Device of Flameproof Electrical Equipment for Mine Use and Its Improvement
LIU Zhi-ping, JIAO Guo-ju
2001, 27(1): 36-37.
Abstract:
Study on Computer Multi-media Teaching System
TIAN Hong
2001, 27(1): 37-38.
Abstract:
The Safety Control of Network Data
LI Jun-min, GONG Shang-fu
2001, 27(1): 39-41.
Abstract:
Begining from the history of developing and changing of data safety problem, the paper expounds the key problems of the safety control of network data at present, analyzes its stratification structure, basic principle and control strategy, importantly discusses related problems about technical carcass and management tool of data safety control.
Model BJJ-660 Mine Use Flameproof Fast Leakage Relay in Low-voltage
MING Dao-jun, GAO Zhu-zhe
2001, 27(1): 42-43.
Abstract:
Development of New Model Multi-function Flow Meter
CHEN Ping, WU Wen-qi
2001, 27(1): 44-45.
Abstract: